105U-G Wirless Gateway
ELPRO’s 105U-G series multi-hop repeat five times, support a variety of industrial protocols and can be combined with ELPRO’s 105/505U-I/O and 115S products to create simple to complex I/O and databus networks.
Using fixed frequency radio bands – Europe, Africa, Asia, Australia / NZ. Covers licensed radio channels in most countries.
Description
Applications:
PLC – PLC, Similar/ dissimilar databuses, SCADA System and remote PLC connection, One way and Multi I/O interconnection to PLCs and DCS/ HMI, Moving machinery, PLC to PLC/ HMI connection, Databus cable replacement, Smart instrument interface and connection
Features:
-
AC/ DC/ battery power options and UPS battery charger and solar regulator.
-
Interconnects similar/ dissimilar industrial protocols (Master/ Slave, Slave/ Slave, Master/ Master) connecting to databus at full speed (eg 12 Mbps Profibus).
-
Eight on-board digital I/O which can be configured as either inputs or outputs. Additional internal I/O points include low/normal supply/ battery voltage (analog).
-
Point to multi-point connectivity with forward error correction, communications integrity check with security encryption.
-
Online read/ write of register I/O, reporting of signal strength (RSSI) with diagnostics including radio path measurement and communications logging.
-
Class I Div 2 hazardous areas approval (USA/Canada).
Models Available:
105/905U-G-MD1
Modbus RTU (Master & Slave), DF1
Up to 4300 I/O points: analog and/or discrete
Modbus – RS232/ 485: 300-19200 bps
DF1 (full duplex) – RS232: 300-19200 bps
105/905U-G-ET1
EtherNet IP, Modbus TCP, TCP/ IP functions
2048 bytes input and 2048 bytes output
(Up to 4300 D I/O or up to 1024 AI/ 1024 AO)
10/100 Mbps, RJ45 connector (transformer isolated interface)
EtherNet/IP Level 2 I/O Server
Modbus/ TCP Class 0, 1 (partially class 2 Slave)
Embedded Web system (Dynamic HTTP)
On-board file system for user downloadable web pages through FTP server; Email (SMTP)
105/905U-G-PR1
Profibus DP Slave; 416 I/O bytes
(Up to 1952 DI/ 1952 DO or up to 122 AI/ 122 AO)
RS-485 optically isolated with onboard DC/ DC converter
Automatic baud rate detection: 9600 bps – 12 Mbps
Profibus DP to EN 50170 standard
105/905U-G-PR2
Profibus DP Master; 2048 bytes input and 2048 bytes output
(Up to 4300 D I/O or up to 1024 AI/ 1024 AO)
RS-485 optically isolated with onboard DC/ DC converter
Automatic baud rate detection: 9600 bps – 12 Mbps
Profibus DP to EN 50170 standard
105/905U-G-DE1
DeviceNet Slave
512 bytes input and 512 bytes output
(Up to 4300 DI I/O points or up to 256 AI/ 256 AO)
Register size 16 bit – number of remote 905U addresses 500
RS422 optically isolated
Selectable baud rate between 125, 250, 500 Kbps
105/905U-G-M+1
Modbus Plus Slave
2048 bytes input and 2048 bytes output
(Up to 4300 D I/O or up to 1024 AI/ 1024 AO)
RS485 optically isolated
Standard baud rate 1 Mbps
Global data base transactions – routing for up to six networks
Spotcom Catalog Numbers:
ELR12 EL-105U-G-MD1-460-500M-* I/O = (8)DIO, Modbus RTU, DF1
ELR13 EL-105U-G-MD1-868-500M I/O = (8)DIO, Modbus RTU, DF1
ELR14 EL-105U-G-PR1-460-500M-* I/O = (8)DIO, Profibus DP Slave
ELR15 EL-105U-G-PR1-460-5W I/O = (8)DIO, Profibus DP Slave
ELR16 EL-105U-G-PR1-868-500M I/O = (8)DIO, Profibus DP Slave
ELR17 EL-105U-G-PR2-460-500M-* I/O = (8)DIO, Profibus DP Master
ELR18 EL-105U-G-PR2-868-500M I/O = (8)DIO, Profibus DP Master